Effect of psycho-educational interventions on quality of life in patients with implantable cardioverter defibrillators: a meta-analysis of randomized controlled trials

Abstract

Background

Implantable cardioverter defibrillators (ICD) were developed for primary and secondary prevention of sudden cardiac death. However, ICD recipients’ mortality is significantly predicted by their quality of life (QOL). The aim of this meta-analysis was to evaluate the effects of psycho-educational interventions on QOL in patients with ICDs.

Methods

We systematically searched PubMed, Medline, Cochrane Library, and CINAHL through April 2015 and references of relevant articles. Studies were reviewed if they met following criteria: (1) randomized controlled trial, (2) participants were adults with an ICD, and (3) data were sufficient to evaluate the effect of psychological or educational interventions on QOL measured by the SF-36 or SF-12. Studies were independently selected and their data were extracted by two reviewers. Study quality was evaluated using a modified Jadad scale. The meta-analysis was conducted using the Cochrane Collaboration’s Review Manager Software Package (RevMan 5). Study heterogeneity was assessed by Q statistics and I 2 statistic. Depending on heterogeneity, data were pooled across trials using fixed-effect or random-effect modeling.

Results

Seven randomized controlled trials fulfilled the inclusion and exclusion criteria, and included 1017 participants. The psycho-educational interventions improved physical component summary (PCS) scores in the intervention groups more than in control groups (mean difference 2.08, 95 % CI 0.86 to 3.29, p < 0.001), but did not significantly affect mental component summary (MCS) scores (mean difference 0.84, 95 % CI -1.68 to 3.35, p = 0.52).

Conclusion

Our meta-analysis demonstrates that psycho-educational interventions improved the physical component, but not the mental component of QOL in patients with ICDs.

Background

Implantable cardioverter defibrillator (ICD) has been established as an efficient treatment for primary and secondary prevention of sudden cardiac death [14]. Thus, the number of ICD implantations worldwide is growing exponentially every year. In the United States, the ICD implantation rate increased from 6.1 % in 1993 to 46.2 % in 2006, with the average rate significantly increasing 17.9 % per year (95 % confidence interval [CI]: 17.6-18.3 %, p < 0.001) [5]. In Australia, the number of ICD implantations nationwide increased from 708 in 2000 to 3198 in 2009, with the implantation rate significantly increasing 19.2 % per year (p < 0.001) [6].

Once the device is implanted, patients face various ICD-related changes that affect their quality of life (QOL). For example, patients with ICDs in a systematic review of qualitative studies were found to experience changes that were both physical (e.g., discomfort, sleep disturbance, fatigue) and psychological (e.g., fear of shocks from the ICD, uncertainty about the future, worry about ICD function), which negatively affected their daily activities and QOL [7]. Several other factors related to worse QOL have been identified in patients with ICDs, such as worry about the duration and number of shocks [711], uncertainty in daily life [12], anxiety [9, 13, 14], feeling loss of control in life [7, 9], ICD-related concerns [10], lower level of device-related acceptance [13], depression [14, 15], high comorbidity burden [16], Type D personality [17], and negative attitudes toward technology dependency [18]. A significant proportion of ICD recipients experience psychological distress. Indeed, 11–28 % of ICD patients were diagnosed as depressed [1921], and furthermore a systematic review of 45 studies indicated that 5–41 % of ICD patients had elevated depressive symptoms when assessed by self-report instruments [22]. In the same systematic review with more than 5000 ICD recipients, 11–26 % of patients were diagnosed with anxiety disorders [22]. Thus, healthcare providers should be concerned not only with how long patients live (their quantity of life) with an ICD, but also their QOL.

Drawing overall conclusions about the effect of an ICD on QOL is difficult because of inconsistent results reported [23]. For example, ICD recipients in a systematic review of studies from 1994 to 2006 had better QOL than patients treated with antiarrhythmic medication, but worse than that of the general public or patients with pacemakers [18]. On the other hand, a more recent study found varying results in 80 ICD recipients: 44.7, 20.7, and 34.2 % had no change in QOL, worse QOL, and better QOL, respectively, after implantation [9]. Furthermore, a study conducted in Hong Kong showed that the 85 ICD recipients in this study had a lower level of QOL compared with the general population [13]. In contrast, QOL (SF-36 scores) of 300 patients with ICDs was improved in all domains during the 1-year follow-up, except for the emotional role functioning domain [24].

Quality of life is an important outcome for patients with ICDs since it predicts survival in the first year after implantation [25]. Moreover, the psychological aspects of QOL were cited by the American Heart Association as desirable outcomes of psychological and educational interventions for ICD patients [26]. The return to normal QOL in ICD patients has been shown to be facilitated by structured follow-up and the development of psycho-educational intervention programs [7, 10, 2729].

During the past decade, various psychological and educational interventions have been designed and provided to ICD patients. Moreover, the effectiveness of these interventions in improving ICD patients’ QOL has been examined in several randomized controlled trials. However, the current evidence for the effectiveness of these trials has not been comprehensively reviewed. Therefore, the aim of this systematic review and meta-analysis was to evaluate the overall effectiveness of psycho-educational interventions on QOL in patients with ICDs.

Methods

This systematic review and meta-analysis was guided by the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guideline [30].

Search strategy

We systematically searched the literature in following databases: Medline, PubMed, Cochrane Library, and CINAHL. The databases were searched from inception to April 2015. Search key words used were “implantable cardioverter defibrillator,” “psychosocial intervention,” “psychological intervention,” “psycho-education intervention,” and “quality of life.” We also used Medical Subject Headings (MeSH) to identify the terminology of key words. To find additional studies and data, we hand searched the references of relevant publications and contacted the authors.

Study selection criteria

Studies were eligible for review if they met following criteria: (1) a randomized controlled trial, (2) subjects were adult patients with ICDs, (3) a psycho-educational intervention was administered, (4) QOL was measured using the SF-36 or SF-12, and (5) written in English or Chinese.

We selected SF-36 or SF-12 scores as the outcome indicator for QOL to preserve sufficient homogeneity for meta-analysis because these instruments have good properties and are the most widely used to measure QOL in studies on the ICD population internationally [8]. SF-36 or SF-12 scores are calculated and aggregated into two summary scores, a mental component summary score (MCS), and a physical component summary score (PCS) [31, 32].

Quality assessment

The methodological quality of each trial was independently evaluated by two reviewers (CWK and TYC) using a quality-assessment scale. [33]. This Jadad scale includes 11 items: (1) Was the study designed as randomized? (2) Was the study designed as double blind? (3) Was there a description of withdrawals and drop outs? (4) Were the objects of the study defined? (5) Were the outcome measures defined clearly? (6) Was there a clear description of the inclusion and exclusion criteria? (7) Was the sample size justified? (8) Was there a clear description of the interventions? (9) Was there at least one control group? (10) Was the method used to assess adverse effects described? (11) Were the methods of statistical analysis described? The maximum possible score was 13, and more than nine points was identified as good. Any disagreements in the quality evaluation between two reviewers were resolved by discussion.

Data extraction

Each selected article was examined to abstract the following data: title of study, authors, publication year, sample size (number of participants in the experimental and control groups), participants’ age and sex, intervention details (type, course, duration, and follow-up), type of control, and the SF-36 or SF-12 score at less than 6 months post-intervention. To assure the accuracy of data extraction, two reviewers abstracted data independently, and discussed any inconsistencies to reach consensus.

Data analysis and synthesis

The meta-analysis was conducted using RevMan 5.3 (Cochrane Collaboration) software. SF-36 or SF-12 scores are continuous data, which were analyzed as mean differences and 95 % CIs. The statistical heterogeneity among trials was measured by Q statistics and I2. Higher values of I2 indicate greater heterogeneity, with I2 values of 25, 50, and 75 % signifying mild, moderate, and high heterogeneity, respectively [34, 35]. Depending on the heterogeneity findings, data were pooled to estimate the overall effect of all interventions by random-effect or fixed-effect modeling. Publication bias was assessed using the funnel plot method, whose asymmetrical shape shows bias [36].

Results

Characteristics of trials

The flow diagram for the study selection process is presented in Fig. 1. Of the 151 articles retrieved from our initial search, we reviewed abstracts and removed 35 duplicate articles and 88 articles that were inconsistent with the aim of the meta-analysis. Among the remaining 28 full-length articles, we excluded 17 studies that did not meet the inclusion criteria. Among the remaining 11 studies, four were not included. One study did not provide the mean and standard deviation of SF-36 scores even after we contacted the authors [37], one study had high dropout rates in each group [38], and two studies [39, 40] analyzed the long-term follow-up outcome of one randomized controlled trial, but we already included the post-intervention outcomes of this trial in our analysis. Therefore, the final data analysis included seven studies [4147] (Table 1).

Fig. 1
figure 1

Flow diagram for study selection process

Table 1 Characteristics of included RCTs

These seven studies included 1017 ICD recipients as participants, with 516 randomly assigned to the experimental group, and 501 to the control group. The majority of participants were male (80.4 %, n = 818), with mean age across the studies ranging from 55.9 to 64.4 years, and mean ejection fraction lower than 35 % in five studies [4143, 45, 47] and not reported in two studies [44, 46]. QOL outcomes were measured in four studies with the SF-12 [42, 4547], and in three studies using the SF-36 [41, 43, 44].

Table 2 presents the quality assessment of the reviewed studies according to the 11-item Jadad Scale. Five studies had Jadad scores ≥ 9 points, indicating good quality [33]. Two studies had Jadad scores of eight points because they did not meet four of the 11 criteria: double blind, description of dropouts, sample size justified, and report of adverse effects.

Table 2 Quality assessment of the included RCTs

Effect of psycho-educational intervention on QOL

The effect of psycho-educational interventions on QOL was examined by separately considering the effects on PCS and MCS, respectively. For the intervention effect on PCS, we used fixed-effect modeling since no heterogeneity was detected among trials (χ2 = 2.51, p = 0.87; I2 = 0 %). The mean difference in PCS scores between experimental and control groups in all seven studies was estimated as 2.08 (95 % CI 0.86 to 3.29, p < 0.001). This result indicates that the psycho-educational interventions significantly improved the physical component of QOL in patients with ICDs (Fig. 2).

Fig. 2
figure 2

Forest plot of mean differences in physical component summary scores (PCS)

For the intervention effect on MCS, we used random-effect modeling since heterogeneity was identified among trials (χ 2 = 21.33, p = 0.002; I2 = 72 %). The mean difference in MCS scores between the experimental and control groups was estimated as 0.84 (95 % CI -1.68 to 3.35, p = 0.52), indicating that the psycho-educational interventions were not effective in improving the mental component of QOL in patients with ICDs (Fig. 3). Since ICD patients’ anxiety and depressive symptoms have been suggested to respond to cognitive behavioral therapy (CBT), we conducted a subgroup analysis of three randomized control trials that used CBT approaches in their interventions [43, 45, 46] to determine if these interventions were effective for the mental component of QOL. The effectiveness of these studies in improving MCS was assessed using random-effect modeling since heterogeneity was identified among trials (χ2 = 10.64, p = 0.005; I2 = 81 %). The mean difference in MCS scores between the experimental and control groups was 3.29 (95 % CI -3.16 to 9.73, p = 0.32). The result revealed that using the CBT approach in the psycho-educational interventions for ICD patients was still not significantly effective in improving their mental component of QOL.

Fig. 3
figure 3

Forest plot of mean differences in mental component summary scores (MCS)

As two studies had Jadad scores of 8 points, we eliminated these two studies and conducted a meta-analysis of five randomized controlled trials [4144, 47]. The psycho-educational interventions still significantly improved the physical component of QOL (95 % CI 0.65 to 3.19, p = 0.003), but not the mental component of QOL (95 % CI -3.46 to 1.47, p = 0.43) in patients with ICDs.

Publication bias

Our funnel plot assessment of PCS and MCS showed no evidence of asymmetry, indicating the absence of publication bias.

Discussion

Our systematic review and meta-analysis of seven randomized controlled trials on 1017 ICD patients provides evidence that psycho-educational interventions effectively improve the physical component but not the mental component of patients’ QOL. Although the majority of recipients regard the ICD as a life-saving medical device that offers them a new chance in life [24, 48], they are affected physically and emotionally by adjustments to the ICD [7]. The psycho-education interventions in the seven reviewed studies were designed to improve recipients’ physical capacity, self-management of ICD-specific care, and self-perceived health [4147]. The psycho-education interventions included exercise training, psycho-education, problem-solving, ICD-specific education and recovery management, as well as relaxation training. ICD recipients in the experimental groups received more information and strategies to deal with life changes related to ICD implantation, which may have improved their perceived health. Finally, the findings of this meta-analysis indicate that the psycho-educational interventions effectively and significantly improved the physical component of ICD recipients’ QOL (PCS).

Most of the psycho-educational interventions in the seven randomized controlled trials we analyzed aimed to deal with ICD patients’ documented psychological distress and improve their QOL [4147]. However, our meta-analysis did not detect any effectiveness of these psycho-educational interventions in improving the mental component of QOL. This lack of effect may have been due to the psycho-educational interventions not adequately addressing psychological distress. We also conducted the subgroup analysis of three randomized control trials which used CBT in their interventions [43, 45, 46] to determine whether CBT was effective for the mental component of QOL since ICD patients’ anxiety and depressive symptoms have been suggested to respond to CBT [44, 49]. One study provided CBT in eight telephone consultations with supporting literature [43], another study provided CBT with a patient-assisted computerized intervention program [45], and the third study provided CBT in the context of a 6-week or 1-day ICD shock-and-stress management program [46]. However, the finding cannot support a statistically significant effectiveness.

This lack of effect may have been due to low statistical power of the studies. Among these three studies, two had relatively small samples, with only 15 participants in each group [45, 46]. Another contributing factor may have been limitations of the SF-36, which is a generic measurement to assess health status and QOL. Even though the SF-36 is commonly used in ICD population studies, it may not detect ICD-specific QOL outcomes, especially mental health well-being [16]. Indeed, the mental health subscale of the SF-36 was reported to be less sensitive to changes in mental health than the WHO-Five Well-Being Scale [50]. In addition, MCS scoring assigns positive weights to four domains (vitality, social functioning, role-emotional, and emotional well-being) and negative weights to four other domains (physical functioning, role-physical, bodily pain, and general health). [51]. The ICD patients recruited in these seven studies had poor health due to their heart condition. Most of them had a heart failure history in NYHA class III or IV, and left ventricular ejection fraction < 35 % [4147]. Therefore, their responses to questions on the negatively weighted last four domains may have driven down their MCS scores.

Among participants in these seven studies, those in five studies experienced ICD shocks [41, 43, 44, 46, 47], those in one study were reported not to experience any ICD shock during the study [45], and the ICD shock experiences of those in another study were not reported [42]. Most people living with an ICD have to cope with stressful or even traumatic events, including having ICD shocks [52]. ICD shocks can be appropriate or inappropriate (not related to therapeutic outcomes), and all ICD shocks adversely affect patients’ mental health [53]. In one qualitative study, ICD patients described their reactions to receiving a shock as losing consciousness, feeling anxious, fearing death and pain, despairing, and worrying about the device not working effectively [37]. Even worse, patients’ psychological distress was greater due to fear of shocks than to actual shocks [54]. In our meta-analysis, we did not detect any effectiveness of psycho-educational interventions on improving the mental component of ICD patients’ QOL (MCS).

Limitations

The strengths of our study are that it is, to the best of our knowledge, the first meta-analysis of randomized control trials on the effects of psycho-educational interventions on QOL in ICD recipients, the meta-analysis followed the PRISMA guidelines, and we avoided publication bias by hand searching retrieved articles for other studies and tried to contact researchers to ask for unpublished data.

However, this meta-analysis had some limitations. The studies included in the meta-analysis were diverse, with different psycho-educational interventions. To address this issue, we analyzed studies for heterogeneity and, based on these findings, used fixed- or random-effect modeling to pool the data to determine an overall intervention effect. We only included studies published in English or Chinese, which may have introduced publication bias. Finally, only seven studies qualified for inclusion in our meta-analysis, six of which had relatively small samples (<100 participants). Therefore, even though psycho-educational interventions in the original studies [41, 43, 4547] reported improvements in psychological distress, e.g., depression and anxiety, we did not find that the pooled data from the psycho-educational interventions improved the mental component of QOL (MCS) in ICD recipients.

Conclusions

The findings of this meta-analysis provide evidence that psycho-educational interventions improved the physical component of QOL (PCS), but not the mental component of QOL (MCS) in patients with ICDs. Nonetheless, we recommend that healthcare providers should still consider the psycho-social adaptation issues of ICD recipients. Identifying effective psycho-educational interventions for improving QOL in ICD recipients will require conducting large-scale randomized clinical trials. Further long-term evaluation follow-up may be needed to examine the durable effectiveness of psycho-educational interventions in patients with ICDs.

Abbreviations

CBT:

Cognitive behavioral therapy

CI:

Confidence interval

ICD:

Implantable cardioverter defibrillator

MCS:

Mental component summary score

MeSH:

Medical Subject Heading

NYHA:

New York heart association

PCS:

Physical component summary score

PRISMA:

Preferred Reporting Items for Systematic Reviews and Meta-Analysis

QOL:

Quality of life

SF-36:

36-Item Short Form Health Survey

WHO:

World Health Organization

References

  1. Ezekowitz JA, Armstrong PW, McAlister FA. Implantable cardioverter defibrillators in primary and secondary prevention: a systematic review of randomized, controlled trials. Ann Intern Med. 2003;138:445–52.

    Article  PubMed  Google Scholar 

  2. Bokhari F, Newman D, Greene M, et al. Long-term comparison of the implantable cardioverter defibrillator versus amiodarone: eleven-year follow-up of a subset of patients in the Canadian Implantable Defibrillator Study (CIDS). Circulation. 2004;110:112–6.

    Article  CAS  PubMed  Google Scholar 

  3. Greenberg H, Case RB, Moss AJ, et al. Analysis of mortality events in the Multicenter Automatic Defibrillator Implantation Trial (MADIT-II). J Am Coll Cardiol. 2004;43:1459–65.

    Article  PubMed  Google Scholar 

  4. Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter defibrillator for congestive heart failure. N Engl J Med. 2005;352:225–37.

    Article  CAS  PubMed  Google Scholar 

  5. Kurtz SM, Ochoa JA, Lau E, et al. Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillator in the United States: 1993–2006. PACE. 2010;33:705–11.

    Article  PubMed  Google Scholar 

  6. Burch AWT, Wong CX, Sullivan T, et al. Trends in the use of implantable cardioverter defibrillators in Australia: a 10-year nationwide study from 2000-2009. Intern Med J. 2013;43:888–95.

    Article  CAS  PubMed  Google Scholar 

  7. Palacios-Ceña D, Losa-Iglesias ME, Álvarez-López C, et al. Patients, intimate partners and family experiences of implantable cardioverter defibrillators: qualitative systematic review. J Adv Nurs. 2011;67:2537–50.

    Article  PubMed  Google Scholar 

  8. Francis J, Johnson B, Niehaus M. Quality of life in patients with implantable cardioverter defibrillators. Indian Pacing Electrophysiol J. 2006;6:173–81.

    PubMed  PubMed Central  Google Scholar 

  9. Dickerson SS, Kennedy M, Wu YWB, Underhill M, Othman A. Factors related to quality-of-life pattern changes in recipients of implantable defibrillators. Heart Lung. 2010;39:466–76.

    Article  PubMed  Google Scholar 

  10. Thylén I, Dekker RL, Jaarsma T, Strömberg A, Moser DK. Characteristics associated with anxiety, depressive symptoms, and quality-of-life in a large cohort of implantable cardioverter defibrillator recipients. J Psychosom Res. 2014;77:122–7.

    Article  PubMed  Google Scholar 

  11. Mark DB, Anstrom KJ, Sun JL, et al. Quality of life with defibrillator therapy or amiodarone in heart failure. N Engl J Med. 2008;359:999–1008.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  12. Flemme I, Hallberg U, Johansson I, Strömberg A. Uncertainty is a major concern for patients with implantable cardioverter defibrillators. Heart Lung. 2011;40:420–8.

    Article  PubMed  Google Scholar 

  13. Chair SY, Lee CK, Choi KC, Sears SF. Quality of life outcomes in Chinese patients with implantable cardioverter defibrillators. PACE. 2011;34:858–67.

    Article  PubMed  Google Scholar 

  14. Wheeler EC, Pretzer-Aboff I, Hardie T, DiSabatino A, Saylor J, Lucey R. Psychological impact of implantable cardioverter defibrillator on their patients. Dimens Crit Care. 2009;28:176–81.

    Article  Google Scholar 

  15. Hallas CN, Burke JL, White DG, Connelly DT. A prospective 1-year study of changes in neuropsychological functioning after implantable cardioverter- defibrillator surgery. Circ Arrhythm Electrophysiol. 2010;3:170–7.

    Article  PubMed  Google Scholar 

  16. Hoogwegt MT, Kupper N, Jordaens L, Pedersen SS, Theuns DAMJ. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator. Europace. 2013;15:1468–74.

    Article  PubMed  Google Scholar 

  17. Habibovic M, van den Broek KC, Theuns DAMJ, et al. Gender disparities in anxiety and quality of life in patients with an implantable cardioverter-defibrillator. Europace. 2011;13:1723–30.

    Article  PubMed  Google Scholar 

  18. Udlis KA. The impact of technology dependency on device acceptance and quality of life in persons with implantable cardioverter defibrillators. J Cardiovasc Nurs. 2013;28:E65–73.

    Article  PubMed  Google Scholar 

  19. Crow SM, Collins J, Justic M, Goetz R, Adler S. Psychopathology following cardioverter defibrillator implantation. Psychosomatics. 1998;39:305–10.

    Article  CAS  PubMed  Google Scholar 

  20. Godemann F, Butter C, Lampe F, Linden M, et al. Panic disorders and agoraphobia: Side effects of treatment with an implantable cardioverter defibrillator. Clin Cardiol. 2004;27:321–6.

    Article  PubMed  Google Scholar 

  21. Jacq F, Foulldrin G, Savoure A, Anselme F, et al. A comparison of anxiety, depression and quality of life between device shock and nonshock groups in implantable cardioverter defibrillator recipients. Gen Hosp Psychiatry. 2009;31:266–73.

    Article  PubMed  Google Scholar 

  22. Magyar-Russell G, Thombs BD, Cai JX, et al. The prevalence of anxiety and depression in adults with implantable cardioverter defibrillators: a systematic review. J Psychosom Res. 2011;71:223–31.

    Article  PubMed  Google Scholar 

  23. Groeneveld PW, Matta MA, Suh JJ, Heidenreich PA, Shea JA. Costs and quality-of-life effects of implantable cardioverter-defibrillators. Am J Cardiol. 2006;98:1409–15.

    Article  PubMed  Google Scholar 

  24. Starrenburg A, Pedersen S, van den Broek K, Karrier K, Scholten M, van der Palen J. Gender differences in psychological distress and quality of life in patients with ICD 1-year postimplant. PACE. 2014;37:843–52.

    Article  PubMed  Google Scholar 

  25. Kao CW, Friedmann E, Thomas SA. Quality of life predicts one-year survival in patients with implantable cardioverter defibrillators. Qual Life Res. 2010;19:307–15.

    Article  PubMed  Google Scholar 

  26. Dunbar SB, Dougherty CM, Sears SF, et al. Educational and psychological interventions to improve outcomes for recipients of implantable cardioverter defibrillators and their families: a scientific statement from the American Heart Association. Circulation. 2012;126:2146–72.

    Article  PubMed  Google Scholar 

  27. Bostwick JM, Sola CL. An updated review of implantable cardioverter defibrillators induced anxiety, and quality of life. Heart Failure Clin. 2011;7:101–8.

    Article  Google Scholar 

  28. Wilson MH, Engelke MK, Sears SF, Swanson M, Neil JA. Disease-specific quality of life-patient acceptance. J Cardiovasc Nurs. 2013;28:285–93.

    Article  PubMed  Google Scholar 

  29. Cesarino CB, Beccaria LM, Aroni MM, Rodrigues LCC, Pacheco SS. Quality of life of patients with implantable cardioverter-defibrillator: the usage of SF-36 questionnaire. Rev Bras Cir Cardiovasc. 2011;26:238–43.

    PubMed  Google Scholar 

  30. Moher D, Shamseer L, Clarke M, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. System Rev. 2015;4:1–9.

    Article  Google Scholar 

  31. Ware JE. SF-36 health survey update. Spine. 2000;25:3130–9.

    Article  PubMed  Google Scholar 

  32. Ware JE, Kosinski M. Physical & mental health summary scales: a manual for users of version 1. 2nd ed. RI: QualityMetric Incorporated; 2001.

    Google Scholar 

  33. Jadad R, Moore RA, Carrol D, et al. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials. 1996;17:1–12.

    Article  CAS  PubMed  Google Scholar 

  34. Higgins JP, Thompson SG, Deeks JJ, Altman DG. Statistical heterogeneity in systematic reviews of clinical trials: a critical appraisal of guideline and practice. J Health Serv Res Policy. 2002;7:51–61.

    Article  PubMed  Google Scholar 

  35. Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. Br Med J. 2003;327:557–60.

    Article  Google Scholar 

  36. Littell JH, Corcoran J, Pillai V. Systematic reviews and meta-analysis. New York: Oxford University Press; 2008.

    Book  Google Scholar 

  37. Cinar FI, Tosun N, Kose S. Evaluation of an education and follow-up programme for implantable cardioverter defibrillator-implanted patients. J Clin Nurs. 2013;22:2474–86.

    Article  PubMed  Google Scholar 

  38. Lewin RJ, Coulton S, Frizelle DJ, Kaye G, Cox H. A brief cognitive behavioral preimplantation and rehabilitation programme for patients receiving an implantable cardioverter-defibrillator improves physical health and reduces psychological morbidity and unplanned readmissions. Heart. 2009;95:63–9.

    Article  CAS  PubMed  Google Scholar 

  39. Dougherty CM, Thompson EA, Lewis FM. Long-term outcomes of a telephone intervention after an ICD. PACE. 2005;28:1157–67.

    Article  PubMed  Google Scholar 

  40. Christensen AV, Zwisler AD, Svendsen JH, et al. Effect of cardiac rehabilitation in patients with ICD: Are gender differences present? Results from the COPE-ICD trial. PACE. 2015;38:18–27.

    Article  PubMed  Google Scholar 

  41. Berg SK, Pedersen PU, Zwisler AD, et al. Comprehensive cardiac rehabilitation improves outcome for patients with implantable cardioverter defibrillator: findings from the COPE-ICD randomized clinical trial. Eur J Cardiovasc Nurs. 2014;14:34–44.

  42. Habibovic M, Denollet J, Coupers P, et al. E-health to manage distress in patients with an implantable cardioverter-defibrillator: primary results of the WEBCARE trial. Psychosom Med. 2014;76:593–602.

    Article  PubMed  Google Scholar 

  43. Irvine J, Firestone J, Ong L, et al. A randomized controlled trial of cognitive behavior therapy tailored to psychological adaptation to an implantable cardioverter defibrillator. Psychosom Med. 2011;73:226–33.

    Article  PubMed  Google Scholar 

  44. Crössmann A, Schulz SM, Kühlkamp V, et al. A randomized controlled trial of secondary prevention of anxiety and distress in a German sample of patients with implantable cardioverter defibrillator. Psychosom Med. 2010;72:434–41.

    Article  PubMed  Google Scholar 

  45. Kuhl EA, Sears SF, Vazquez LD, Conti JB. Patient-assisted computerized education for recipients of implantable cardioverter defibrillators: a randomized controlled trial of the PACER program. J Cardiovasc Nurs. 2009;24:225–31.

    Article  PubMed  Google Scholar 

  46. Sears SF, Sowell LV, Kuhl EA, et al. The ICD shock and stress management program: a randomized trial of psychosocial treatment to optimize quality of life in ICD patients. PACE. 2007;30:858–64.

    Article  PubMed  Google Scholar 

  47. Dougherty CM, Lewis FM, Thompson EA, Baer JD, Kim W. Short-term efficacy of a telephone intervention by expert nurses after an implantable cardioverter defibrillator. PACE. 2004;27:1594–602.

    Article  PubMed  Google Scholar 

  48. Eckert M, Jones T. How does an implantable cardioverter defibrillator affect the lives of patients and their families? Int J Nurs Pract. 2002;8:152–7.

    Article  PubMed  Google Scholar 

  49. Spek V, Cuijpers P, Nyklicek I, Riper H, Keyzer J, Pop V. Internet-based cognitive behavior therapy for symptoms of depression and anxiety: a meta-analysis. Psychol Med. 2007;37:319–28.

  50. Bech P, Olsen LR, Kjoller M, Rasmussen NK. Measuring well-being rather than the absence of distress symptoms: a comparison of the SF-36 Mental Health subscale and WHO-Five Well-Being Scale. Int J Methods Psychiatr Res. 2003;12:85–91.

    Article  PubMed  Google Scholar 

  51. Farivar SS, Cunningham WE, Hays RD. Correlated physical and mental health summary scores for the SF-36 and SF-12 health survey, v.1. Health and Quality of Life Outcomes. 2007;5:54-61.

  52. Ford J, Sears S, Shea JB, Cahill J. Coping with trauma and stressful events as a patient with an implantable cardioverter-defibrillator. Circulation. 2013;127:e426–30.

    Article  PubMed  Google Scholar 

  53. Borne RT, Varosy PD, Masoudi FA. Implantable cardioverter-defibrillator shocks: epidemiology, outcomes, and therapeutic approaches. JAMA Intern Med. 2013;173:859–65.

    Article  PubMed  Google Scholar 

  54. Vazquez LD, Conti JB, Sears SF. Female-specific education, management, and lifestyle enhancement for implantable cardioverter defibrillator patients: the FEMALWE-ICD study. PACE. 2010;33:1131–40.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We are grateful to the authors who responded to our emails and provided additional information about their studies.

Funding

Not applicable.

Availability of data and material

The data will not be shared because we do not have the raw data. This manuscript reported results of a meta-analysis, which we extracted the data for meta-analysis from published papers.

Authors’ contributions

CWK, MYC, and PHL conducted the systematical search, and data extraction. CWK, MYC, and TYC analyzed the data. CWK and TYC evaluated the quality of each study. CWK wrote the manuscript. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

Not applicable.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chi-Wen Kao.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kao, CW., Chen, MY., Chen, TY. et al. Effect of psycho-educational interventions on quality of life in patients with implantable cardioverter defibrillators: a meta-analysis of randomized controlled trials. Health Qual Life Outcomes 14, 138 (2016). https://doi.org/10.1186/s12955-016-0543-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12955-016-0543-2

Keywords