Skip to main content

Table 7 Sensitivity, specificity, predictive values and likelihood ratios for different cutoff values

From: Validation of the Portuguese version of Amsterdam Preoperative Anxiety and Information Scale (APAIS)

Metric (95% CI)

Cutoff 10

Cutoff 11

Cutoff 12

Cutoff 13

Sensitivity

0.91 (0.81, 0.97)

0.86 (0.76, 0.94)

0.76 (0.64, 0.85)

0.68 (0.56, 0.79)

Specificity

0.49 (0.33, 0.65)

0.60 (0.44, 0.75)

0.79 (0.64, 0.90)

0.84 (0.69, 0.93)

Positive predictive value

0.73 (0.62, 0.82)

0.77 (0.66, 0.86)

0.85 (0.73, 0.93)

0.87 (0.74, 0.94)

Negative predictive value

0.78 (0.58, 0.91)

0.74 (0.57, 0.88)

0.68 (0.53, 0.80)

0.63 (0.49, 0.76)

Positive likelihood ratio

1.78 (1.31, 2.40)

2.18 (1.49, 3.20)

3.62 (1.99, 6.57)

4.19 (2.08, 8.41)

Negative likelihood ratio

0.19 (0.08, 0.42)

0.23 (0.12, 0.43)

0.31 (0.19, 0.48)

0.38 (0.26, 0.55)